The research in our lab focuses on the development of new MRI acquisition technologies that can dramatically improve the speed, sensitivity and specificity of brain imaging. Our research explores approaches in designing tailored data acquisition & reconstruction algorithms using signal processing/optimization/ML methods, to take advantage of the underlying MR Physics and emerging hardware.
The goal is to create new imaging strategies that can help address important clinical & neuroscientific questions. The technologies that we have developed have enabled highly detailed brain data at unprecedented temporal and spatial resolutions, that have helped extract a wealth of quantitative information about brain structure and physiology. Some of these technologies have now been successfully translated as FDA-approved product, that are now being used daily in the clinic on the Siemens, GE and Phillips MRI scanners worldwide.
- – Magn Reson Med
High‐resolution myelin‐water fraction and quantitative relaxation mapping using 3D ViSTa‐MR fingerprinting
Purpose: This study aims to develop a high-resolution whole-brain multi-parametric quantitative MRI approach for simultaneous mapping of myelin-water fraction (MWF), T1, T2, and proton-density (PD), all within a clinically feasible scan time.
- – Magn Reson Med
Rapid and accurate navigators for motion and B0 tracking using QUEEN: Quantitatively enhanced parameter estimation from navigators
Purpose: To develop a framework that jointly estimates rigid motion and polarizing magnetic field (B0) perturbations () for brain MRI using a single navigator of a few milliseconds in duration, and to additionally allow for navigator acquisition at arbitrary timings within any type of sequence to obtain high-temporal resolution estimates.
- – Nat Methods.
Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla
Abstract: To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m-1, 900 T m-1s-1) with an additional third layer of windings.
- – Magn Reson Med
DTI‐MR fingerprinting for rapid high‐resolution whole‐brain T1, T2, proton density, ADC, and fractional anisotropy mapping
Purpose: This study aims to develop a high-efficiency and high-resolution 3D imaging approach for simultaneous mapping of multiple key tissue parameters for routine brain imaging, including T1, T2, proton density (PD), ADC, and fractional anisotropy (FA).