ZHICHENG ZHANG received his Ph.D from University of Chinese Academy of Sciences and B.S. degree from Sun Yat-sen University. He is currently a postdoctoral fellow in Stanford University. From 2017 to 2018, he had been a Visiting scholar with the Virginia Tech-Wake Forest University, School of Biomedical Engineering and Sciences, Virginia Polytechnic Institute and State University, USA. His research interests are medical data analysis, computer vision and deep learning.

Professional Education


  • Ph.D, University of Chinese Academy of Sciences
  • B.S, Sun Yat-Sen University

Stanford Advisors


  • Lei Xing, Postdoctoral Faculty Sponsor

Publications

All Publications


  • Modularized Data-Driven Reconstruction Framework for Non-ideal Focal Spot Effect Elimination in Computed Tomography. Medical physics Zhang, Z., Yu, L., Zhao, W., Xing, L. 2021

    Abstract

    PURPOSE: High-performance computed tomography (CT) plays a vital role in clinical decision making. However, the performance of CT imaging is adversely affected by the non-ideal focal spot size of the X-ray source or degraded by an enlarged focal spot size due to aging. In this work, we aim to develop a deep learning-based strategy to mitigate the problem so that high spatial resolution CT images can be obtained even in the case of a non-ideal X-ray source.METHODS: To reconstruct high-quality CT images from blurred sinograms via joint image and sinogram learning, a cross-domain hybrid model is formulated via deep learning into a modularized data-driven reconstruction (MDR) framework. The proposed MDR framework comprises several blocks, and all the blocks share the same network architecture and network parameters. In essence, each block utilizes two sub-models to generate an estimated blur kernel and a high-quality CT image simultaneously. In this way, our framework generates not only a final high-quality CT image but also a series of intermediate images with gradually improved anatomical details, enhancing the visual perception for clinicians through the dynamic process. We used simulated training datasets to train our model in an end-to-end manner and tested our model on both simulated and realistic experimental datasets.RESULTS: On the simulated testing datasets, our approach increases the information fidelity criterion (IFC) by up to 34.2%, the universal quality index (UQI) by up to 20.3%, the signal-to-noise (SNR) by up to 6.7%, and reduces the root mean square error (RMSE) by up to 10.5% as compared with FBP. Compared with the iterative deconvolution method (NSM), MDR increases IFC by up to 24.7%, UQI by up to 16.7%, SNR by up to 6.0%, and reduces RMSE by up to 9.4%. In the modulation transfer function (MTF) experiment, our method improves the MTF50% by 34.5% and MTF10% by 18.7% as compared with FBP, Similarly remarkably, our method improves MTF50% by 14.3% and MTF10% by 0.9% as compared with NSM. Also, our method shows better imaging results in the edge of bony structures and other tiny structures in the experiments using phantom consisting of ham and a bottle of peanuts.CONCLUSIONS: A modularized data-driven CT reconstruction framework is established to mitigate the blurring effect caused by a non-ideal X-ray source with relatively large focal spot. The proposed method enables us to obtain high-resolution images with less ideal X-ray source.

    View details for DOI 10.1002/mp.14785

    View details for PubMedID 33595900

  • Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images IEEE TRANSACTIONS ON MEDICAL IMAGING Yu, L., Zhang, Z., Li, X., Xing, L. 2021; 40 (1): 228?38

    Abstract

    Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal artifacts and influence clinical diagnosis or dose calculation in radiation therapy. In this article, we propose a generalizable framework for metal artifact reduction (MAR) by simultaneously leveraging the advantages of image domain and sinogram domain-based MAR techniques. We formulate our framework as a sinogram completion problem and train a neural network (SinoNet) to restore the metal-affected projections. To improve the continuity of the completed projections at the boundary of metal trace and thus alleviate new artifacts in the reconstructed CT images, we train another neural network (PriorNet) to generate a good prior image to guide sinogram learning, and further design a novel residual sinogram learning strategy to effectively utilize the prior image information for better sinogram completion. The two networks are jointly trained in an end-to-end fashion with a differentiable forward projection (FP) operation so that the prior image generation and deep sinogram completion procedures can benefit from each other. Finally, the artifact-reduced CT images are reconstructed using the filtered backward projection (FBP) from the completed sinogram. Extensive experiments on simulated and real artifacts data demonstrate that our method produces superior artifact-reduced results while preserving the anatomical structures and outperforms other MAR methods.

    View details for DOI 10.1109/TMI.2020.3025064

    View details for Web of Science ID 000604883800020

    View details for PubMedID 32956044

  • matFR: a matlab toolbox for feature ranking. Bioinformatics (Oxford, England) Zhang, Z. n., Liang, X. n., Qin, W. n., Yu, S. n., Xie, Y. n. 2020

    Abstract

    Nowadays, it is feasible to collect massive features for quantitative representation and precision medicine, and thus, automatic ranking to figure out the most informative and discriminative ones becomes increasingly important. To address this issue, 42 feature ranking (FR) methods are integrated to form a MATLAB toolbox (matFR). The methods apply mutual information, statistical analysis, structure clustering and other principles to estimate the relative importance of features in specific measure spaces. Specifically, these methods are summarized and an example shows how to apply a FR method to sort mammographic breast lesion features. The toolbox is easy to use and flexible to integrate additional methods. Importantly, it provides a tool to compare, investigate and interpret the features selected for various applications.The toolbox is freely available at http://github.com/NicoYuCN/matFR. A tutorial and an example with a data set are provided.

    View details for DOI 10.1093/bioinformatics/btaa621

    View details for PubMedID 32637981

  • Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan MEDICAL PHYSICS Liang, X., Jiang, Y., Zhao, W., Zhang, Z., Luo, C., Xiong, J., Yu, S., Yang, X., Sun, J., Zhou, Q., Niu, T., Xie, Y. 2019; 46 (7): 3165?79

    View details for DOI 10.1002/mp.13568

    View details for Web of Science ID 000475671900022

  • Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan. Medical physics Liang, X., Jiang, Y., Zhao, W., Zhang, Z., Luo, C., Xiong, J., Yu, S., Yang, X., Sun, J., Zhou, Q., Niu, T., Xie, Y. 2019

    Abstract

    PURPOSE: Scatter contamination in the cone-beam CT (CBCT) leads to CT number inaccuracy, spatial non-uniformity, and loss of image contrast. In our previous work, we proposed a single scan scatter correction approach using a stationary partial beam blocker. Although the previous method works effectively on a tabletop CBCT system, it fails to achieve high image quality on a clinical CBCT system mainly due to the wobble of the LINAC gantry during scan acquisition. Due to the mechanical deformation of CBCT gantry, the wobbling effect is observed in the clinical CBCT scan, and more missing data present using the previous blocker with the uniformly distributed lead strips.METHODS: An optimal blocker distribution is proposed to minimize the missing data. In the objective function of the missing data, the motion of the beam blocker in each projection is estimated using the segmentation due to its high contrast in the blocked area. The scatter signals from the blocker are also estimated using an air scan with the inserted blocker. The final image is generated using the forward projection to compensate for the missing data.RESULTS: On the CatphanŠ504 phantom, our approach reduces the average CT number error from 86 Hounsfield unit (HU) to 9 HU and improves the image contrast by a factor of 1.45 in the high-contrast rods. On a head patient, the CT number error is reduced from 97 HU to 6 HU in the soft-tissue region and the image spatial non-uniformity is decreased from 27% to 5%.CONCLUSIONS: The results suggest that the proposed method is promising for clinical applications. This article is protected by copyright. All rights reserved.

    View details for PubMedID 31055835

  • A Technical Review of Convolutional Neural Network-Based Mammographic Breast Cancer Diagnosis COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE Zou, L., Yu, S., Meng, T., Zhang, Z., Liang, X., Xie, Y. 2019: 6509357

    Abstract

    This study reviews the technique of convolutional neural network (CNN) applied in a specific field of mammographic breast cancer diagnosis (MBCD). It aims to provide several clues on how to use CNN for related tasks. MBCD is a long-standing problem, and massive computer-aided diagnosis models have been proposed. The models of CNN-based MBCD can be broadly categorized into three groups. One is to design shallow or to modify existing models to decrease the time cost as well as the number of instances for training; another is to make the best use of a pretrained CNN by transfer learning and fine-tuning; the third is to take advantage of CNN models for feature extraction, and the differentiation of malignant lesions from benign ones is fulfilled by using machine learning classifiers. This study enrolls peer-reviewed journal publications and presents technical details and pros and cons of each model. Furthermore, the findings, challenges and limitations are summarized and some clues on the future work are also given. Conclusively, CNN-based MBCD is at its early stage, and there is still a long way ahead in achieving the ultimate goal of using deep learning tools to facilitate clinical practice. This review benefits scientific researchers, industrial engineers, and those who are devoted to intelligent cancer diagnosis.

    View details for DOI 10.1155/2019/6509357

    View details for Web of Science ID 000464727600001

    View details for PubMedID 31019547

    View details for PubMedCentralID PMC6452645