Seraina A. Dual is a postodoctoral fellow at the departments of Radiology at Stanford Medicine and Mechanical Engineering at Stanford University, mentored by Prof. Doff McElHinney, Prof. Daniel Ennis, and Prof. Alison Marsden. She graduated with a Bachelor's degree from the Federal Institute of Technology Zurich (ETH Zurich) in Mechanical Engineering, a master's degree at ETH Zurich in Mechanical Engineering with a specialization in robotics and biomedical application with Prof. Roger Gassert, and her Dr. of science at ETH Zurich in Mechanical Engineering with Prof. Mirko Meboldt. During this time, she spent some time with Prof. Ellen Kuhl at Stanford University (BSc), with Prof. Theo Chee Leong at National University of Singapore (MSc), and with Prof. Christopher Hayward at the St. Vincent's Hospital in Sydney (DSc). Her work focuses on developing dynamic systems, algorithms, and sensors inspired by her background in engineering and control methodology to either improve our pathophysiological understanding of disease or enable physiological interaction of patients with intelligent medical devices.

Professional Education


  • DSc., ETH Zurich, Mechanical Engineering (2019)
  • MSc., ETH Zurich, Mechanical Engineering - Robotics and Biomedical (2015)
  • BSc., ETH Zurich, Mechanical Engineering (2012)

Stanford Advisors


Publications

All Publications


  • Continuous Heart Volume Monitoring by Fully Implantable Soft Strain Sensor. Advanced healthcare materials Dual, S. A., Llerena Zambrano, B., Sundermann, S., Cesarovic, N., Kron, M., Magkoutas, K., Hengsteler, J., Falk, V., Starck, C., Meboldt, M., Voros, J., Schmid Daners, M. 2020: e2000855

    Abstract

    Cardiothoracic open-heart surgery has revolutionized the treatment of cardiovascular disease, the leading cause of death worldwide. After the surgery, hemodynamic and volume management can be complicated, for example in case of vasoplegia after endocarditis. Timely treatment is crucial for outcomes. Currently, treatment decisions are made based on heart volume, which needs to be measured manually by the clinician each time using ultrasound. Alternatively, implantable sensors offer a real-time window into the dynamic function of our body. Here it is shown that a soft flexible sensor, made with biocompatible materials, implanted on the surface of the heart, can provide continuous information of the heart volume after surgery. The sensor works robustly for a period of two days on a tensile machine. The accuracy of measuring heart volume is improved compared to the clinical gold standard in vivo, with an error of 7.1mL for the strain sensor versus impedance and 14.0mL versus ultrasound. Implanting such a sensor would provide essential, continuous information on heart volume in the critical time following the surgery, allowing early identification of complications, facilitating treatment, and hence potentially improving patient outcome.

    View details for DOI 10.1002/adhm.202000855

    View details for PubMedID 32893478

  • Ultrasound-based prediction of interventricular septum positioning during left ventricular support-an experimental study. Journal of cardiovascular translational research Dual, S. A., Anthamatten, L., Shah, P., Meboldt, M., Schmid Daners, M. 2020

    Abstract

    The implantation of left ventricular assist devices (LVADs) is often complicated by arrhythmias and right ventricular failure (RVF). Today, the pump speed is titrated to optimize device support using single observations of interventricular septum (IVS) positioning with echocardiographic ultrasound (US). The study demonstrates the applicability of three integrated US transducers in the LVAD cannula to monitor IVS positioning continuously and robustly in real time. In vitro, the predictor of the IVS shift shows an overall prediction error for all volume states of less than 20% and provides a continuous assessment for 99% of cases in four differently sized heart phantoms. The prediction of IVS shift depending on the cannula position is robust for azimuthal and polar deviations of ± 20° and ± 8°, respectively. This intracardiac US concept results in a viable predictor for IVS positioning and represents a promising approach to continuously monitor the IVS and ventricular loading in LVAD patients. Graphical abstract.

    View details for DOI 10.1007/s12265-020-10034-3

    View details for PubMedID 32671647

  • Short-term physiological response to high-frequency-actuated pVAD support ARTIFICIAL ORGANS Rebholz, M., Dual, S., Batliner, M., Meboldt, M., Daners, M. 2019; 43 (12): 1170–81

    Abstract

    Ventricular assist devices (VADs) are an established treatment option for heart failure (HF). However, the devices are often plagued by material-related hemocompatibility issues. In contrast to continuous flow VADs with high shear stresses, pulsatile VADs (pVADs) offer the potential for an endothelial cell coating that promises to prevent many adverse events caused by an insufficient hemocompatibility. However, their size and weight often precludes their intracorporeal implantation. A reduction of the pump body size and weight of the pump could be achieved by an increase in the stroke frequency while maintaining a similar cardiac output. We present a new pVAD system consisting of a pump and an actuator specifically designed for actuation frequencies of up to 240 bpm. In vitro and in vivo results of the short-term reaction of the cardiovascular system show no significant changes in left ventricular and aortic pressure between actuation frequencies from 60 to 240 bpm. The aortic pulsatility increases when the actuation frequency is raised while the heart rate remains unaffected in vivo. These results lead us to the conclusion that the cardiovascular system tolerates short-term increases of the pVAD stroke frequencies.

    View details for DOI 10.1111/aor.13521

    View details for Web of Science ID 000479706100001

    View details for PubMedID 31211873

  • Acute changes in preload and the QRS amplitude in advanced heart failure patients BIOMEDICAL PHYSICS & ENGINEERING EXPRESS Dual, S., Pergantis, P., Schoenrath, F., Keznickl-Pulst, J., Falk, V., Meboldt, M., Daners, M. 2019; 5 (4)
  • Ultrasonic sensor concept to fit a ventricular assist device cannula evaluated using geometrically accurate heart phantoms ARTIFICIAL ORGANS Dual, S., Zimmermann, J., Neuenschwander, J., Cohrs, N., Solowjowa, N., Stark, W., Meboldt, M., Daners, M. 2019; 43 (5): 467–77

    Abstract

    Future left ventricular assist devices (LVADs) are expected to respond to the physiologic need of patients; however, they still lack reliable pressure or volume sensors for feedback control. In the clinic, echocardiography systems are routinely used to measure left ventricular (LV) volume. Until now, echocardiography in this form was never integrated in LVADs due to its computational complexity. The aim of this study was to demonstrate the applicability of a simplified ultrasonic sensor to fit an LVAD cannula and to show the achievable accuracy in vitro. Our approach requires only two ultrasonic transducers because we estimated the LV volume with the LV end-diastolic diameter commonly used in clinical assessments. In order to optimize the accuracy, we assessed the optimal design parameters considering over 50 orientations of the two ultrasonic transducers. A test bench was equipped with five talcum-infused silicone heart phantoms, in which the intra-ventricular surface replicated papillary muscles and trabeculae carnae. The end-diastolic LV filling volumes of the five heart phantoms ranged from 180 to 480 mL. This reference volume was altered by ±40 mL with a syringe pump. Based on the calibrated measurements acquired by the two ultrasonic transducers, the LV volume was estimated well. However, the accuracies obtained are strongly dependent on the choice of the design parameters. Orientations toward the septum perform better, as they interfere less with the papillary muscles. The optimized design is valid for all hearts. Considering this, the Bland-Altman analysis reports the LV volume accuracy as a bias of ±10% and limits of agreement of 0%-40% in all but the smallest heart. The simplicity of traditional echocardiography systems was reduced by two orders of magnitude in technical complexity, while achieving a comparable accuracy to 2D echocardiography requiring a calibration of absolute volume only. Hence, our approach exploits the established benefits of echocardiography and makes them applicable as an LV volume sensor for LVADs.

    View details for DOI 10.1111/aor.13379

    View details for Web of Science ID 000467448200006

    View details for PubMedID 30357874

  • ConVes: The Sutureless Aortic Graft Anastomotic Device ANNALS OF THORACIC SURGERY Dual, S., Muller, A., Boes, S., Brinkmann, O., Steffanoni, S., Falk, V., Meboldt, M., Daners, M., Sundermann, S. 2018; 105 (5): 1558–62

    Abstract

    Less invasive left ventricular assist device implantation became feasible with the development of smaller devices. This study evaluated a sutureless aortic anastomosis device to facilitate the implant procedure.The novel anastomotic device deploys and anchors an acute-angled stent in the aortic wall to create a sutureless outflow graft anastomosis in the ascending aorta. Four aortic anastomoses were performed on the beating hearts of two pigs without cross-clamping or cardiopulmonary bypass.The procedure was fast and simple. The time of anastomosis averaged 8.1 minutes, with merely oral instructions to the operating surgeon. The design of the stent allowed the outflow graft to be implanted with the intended angulation of 45 degrees.This proof-of-concept study demonstrates the feasibility and short-term success of the proposed sutureless anastomotic device. Further preclinical studies are necessary to evaluate long-term durability of the anastomosis.

    View details for DOI 10.1016/j.athoracsur.2017.11.010

    View details for Web of Science ID 000430515700055

    View details for PubMedID 29530280

  • Standardized Comparison of Selected Physiological Controllers for Rotary Blood Pumps: In Vitro Study ARTIFICIAL ORGANS Petrou, A., Lee, J., Dual, S., Ochsner, G., Meboldt, M., Daners, M. 2018; 42 (3): E29–E42

    Abstract

    Various physiological controllers for left ventricular assist devices (LVADs) have been developed to prevent flow conditions that may lead to left ventricular (LV) suction and overload. In the current study, we selected and implemented six of the most promising physiological controllers presented in literature. We tuned the controllers for the same objectives by using the loop-shaping method from control theory. The in vitro experiments were derived from literature and included different preload, afterload, and contractility variations. All experiments were repeated with an increased or decreased contractility from the baseline pathological circulation and with simulated sensor drift. The controller performances were compared with an LVAD operated at constant speed (CS) and a physiological circulation. During preload variations, all controllers resulted in a pump flow change that resembled the cardiac output response of the physiological circulation. For afterload variations, the response varied among the controllers, whereas some of them presented a high sensitivity to contractility or sensor drift, leading to LV suction and overload. In such cases, the need for recalibration of the controllers or the sensor is indicated. Preload-based physiological controllers showed their clinical significance by outperforming the CS operation and promise many benefits for the LVAD therapy. However, their clinical implementation in the near future for long-term use is highly dependent on the sensor technology and its reliability.

    View details for DOI 10.1111/aor.12999

    View details for Web of Science ID 000426840000001

    View details for PubMedID 29094351