Bio

Clinical Focus


  • Diagnostic Radiology

Academic Appointments


Honors & Awards


  • John Kirkpatrick Young Investigator Award, Society of Pediatric Radiology (2020)

Professional Education


  • Board Certification: American Board of Radiology, Diagnostic Radiology (2019)
  • Fellowship: Lucile Packard Childrens Hospital Pediatric Radiology Fellowship (2019) CA
  • Residency: Mallinckrodt Institute of Radiology Washington University Radiology Residency (2018) MO
  • Internship: University of North Carolina Pediatric Residency (2014) NC
  • Medical Education: UCLA David Geffen School Of Medicine Registrar (2013) CA
  • Fellowship, Lucile Packard Children?s Hospital, Stanford University Medical Center, Pediatric Radiology, Advanced MRI, Pediatric Musculoskeletal Radiology (2020)
  • Residency, Mallinckrodt Institute of Radiology at Washington University, Radiology (2018)
  • Internship, University of North Carolina Children?s Hospital, Pediatrics (2014)
  • M.D., David Geffen School of Medicine at UCLA, Medical Doctorate (2013)
  • BSE, Duke University, Biomedical Engineering (2008)

Research & Scholarship

Current Research and Scholarly Interests


Current research interests include ultrasound elastography, ultrasound contrast applications, MRI sequence development, HIFU and MSK ultrasound.

Publications

All Publications


  • Dynamic Hydrodissection for Skin Protection during Cryoablation of Superficial Lesions. Journal of vascular and interventional radiology : JVIR Sandberg, J. K., Shoaf, K. R., Lungren, M. P., Young, V. A., Josephs, S., Thakor, A. S. 2020

    View details for DOI 10.1016/j.jvir.2020.01.025

    View details for PubMedID 32418774

  • Contrast enhanced ultrasound: comparing a novel modality to MRI to assess for bowel disease in pediatric Crohn's patients TRANSLATIONAL GASTROENTEROLOGY AND HEPATOLOGY Mudambi, K., Sandberg, J., Bass, D., Rubesova, E. 2020; 5
  • Imaging Characteristics of Nephrogenic Rests Versus Small Wilms Tumors: A Report From the Children's Oncology Group Study AREN03B2. AJR. American journal of roentgenology Sandberg, J. K., Chi, Y. Y., Smith, E. A., Servaes, S., Hoffer, F. A., Mullen, E. A., Perlman, E. J., Tornwall, B., Ehrlich, P. F., Geller, J. I., Grundy, P. E., Fernandez, C. V., Dome, J. S., Khanna, G. 2020: 1?8

    Abstract

    OBJECTIVE. Distinguishing nephrogenic rests from small Wilms tumors can be challenging. This retrospective study was performed to determine if imaging characteristics can be used to distinguish nephrogenic rests from Wilms tumors. MATERIALS AND METHODS. All cases of pathologically confirmed nephrogenic rests and Wilms tumors smaller than 5 cm in maximum dimension on imaging in patients younger than 5 years old were identified from the Children's Oncology Group AREN03B2 study (July 2006-August 2016). Exclusion criteria were chemotherapy before pathologic evaluation or more than 30 days between imaging and surgery; in addition, patients with nephrogenic rests occurring within or juxtaposed to a Wilms tumor and patients with diffuse hyperplastic perilobar nephroblastomatosis were excluded. Two radiologists who were blinded to pathology results assessed all lesions. The two-sample t test was used for continuous variables, and the Fisher exact test was used for categoric variables. ROC analysis was performed to determine the optimal size cutoff for distinguishing between nephrogenic rests and Wilms tumors. RESULTS. Thirty-one pathologically confirmed rests (20 perilobar, 11 intralobar) and 26 Wilms tumors smaller than 5 cm met the eligibility criteria for study inclusion. The median diameter of the nephrogenic rests was 1.3 cm (range, 0.7-3.4 cm) and the median diameter of the Wilms tumor was 3.2 cm (range, 1.8-4.9 cm) (p < 0.001). Imaging findings supportive of Wilms tumors were spherical (p < 0.001) and exophytic (p < 0.001) lesions. Perilobar rests (17/20) were more likely to be homogeneous than intralobar rests (3/11) or Wilms tumor (3/26) (p < 0.001). ROC analysis showed that the optimal size cutoff for distinguishing between nephrogenic rests and Wilms tumors was 1.75 cm. CONCLUSION. In children younger than 5 years old, the diagnosis of a Wilms tumor should be favored over a nephrogenic rest when a renal mass is spherical, exophytic, or larger than 1.75 cm. Homogeneity favors the diagnosis of perilobar nephrogenic rests, whereas intralobar rests and Wilms tumors are more likely to be inhomogeneous.

    View details for DOI 10.2214/AJR.19.22301

    View details for PubMedID 32160052

  • Targeted rapid knee MRI exam using T-2 shuffling JOURNAL OF MAGNETIC RESONANCE IMAGING Tamir, J. I., Taviani, V., Alley, M. T., Perkins, B. C., Hart, L., O'Brien, K., Wishah, F., Sandberg, J. K., Anderson, M. J., Turek, J. S., Willke, T. L., Lustig, M., Vasanawala, S. S. 2019; 49 (7): E195?E204

    View details for DOI 10.1002/jmri.26600

    View details for Web of Science ID 000474612300019

  • Targeted rapid knee MRI exam using T2 shuffling. Journal of magnetic resonance imaging : JMRI Tamir, J. I., Taviani, V., Alley, M. T., Perkins, B. C., Hart, L., O'Brien, K., Wishah, F., Sandberg, J. K., Anderson, M. J., Turek, J. S., Willke, T. L., Lustig, M., Vasanawala, S. S. 2019

    Abstract

    BACKGROUND: MRI is commonly used to evaluate pediatric musculoskeletal pathologies, but same-day/near-term scheduling and short exams remain challenges.PURPOSE: To investigate the feasibility of a targeted rapid pediatric knee MRI exam, with the goal of reducing cost and enabling same-day MRI access.STUDY TYPE: A cost effectiveness study done prospectively.SUBJECTS: Forty-seven pediatric patients.FIELD STRENGTH/SEQUENCE: 3T. The 10-minute protocol was based on T2 Shuffling, a four-dimensional acquisition and reconstruction of images with variable T2 contrast, and a T1 2D fast spin-echo (FSE) sequence. A distributed, compressed sensing-based reconstruction was implemented on a four-node high-performance compute cluster and integrated into the clinical workflow.ASSESSMENT: In an Institutional Review Board-approved study with informed consent/assent, we implemented a targeted pediatric knee MRI exam for assessing pediatric knee pain. Pediatric patients were subselected for the exam based on insurance plan and clinical indication. Over a 2-year period, 47 subjects were recruited for the study and 49 MRIs were ordered. Date and time information was recorded for MRI referral, registration, and completion. Image quality was assessed from 0 (nondiagnostic) to 5 (outstanding) by two readers, and consensus was subsequently reached.STATISTICAL TESTS: A Wilcoxon rank-sum test assessed the null hypothesis that the targeted exam times compared with conventional knee exam times were unchanged.RESULTS: Of the 49 cases, 20 were completed on the same day as exam referral. Median time from registration to exam completion was 18.7 minutes. Median reconstruction time for T2 Shuffling was reduced from 18.9 minutes to 95 seconds using the distributed implementation. Technical fees charged for the targeted exam were one-third that of the routine clinical knee exam. No subject had to return for additional imaging.DATA CONCLUSION: The targeted knee MRI exam is feasible and reduces the imaging time, cost, and barrier to same-day MRI access for pediatric patients.LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019.

    View details for PubMedID 30637847

  • Near-silent distortionless DWI using magnetization-prepared RUFIS. Magnetic resonance in medicine Yuan, J., Hu, Y., Menini, A., Sandino, C. M., Sandberg, J., Sheth, V., Moran, C. J., Alley, M., Lustig, M., Hargreaves, B., Vasanawala, S. 2019

    Abstract

    To develop a near-silent and distortionless DWI (sd-DWI) sequence using magnetization-prepared rotating ultrafast imaging sequence.A rotating ultrafast imaging sequence was modified with driven-equilibrium diffusion preparation, including eddy-current compensation methods. To compensate for the T1 recovery during readout, a phase-cycling method was used. Both compensation methods were validated in phantoms. The optimized sequence was compared with an EPI diffusion sequence for image distortion, contrast, ADC, and acoustic noise level in phantoms. The sequence was evaluated in 1 brain volunteer, 5 prostate volunteers, and 10 pediatric patients with joint diseases.Combination of several eddy-current compensation methods reduced the artifact to an acceptable level. Phase cycling reduced T1 recovery contamination during readout. In phantom scans, the optimized sequence generated similar image contrast to the EPI diffusion sequence, and ADC maps between the sequences were comparable; sd-DWI had significantly lower acoustic noise (P < .05). In vivo brain scan showed reduced image distortion in sd-DWI compared with the EPI diffusion, although residual motion artifact remains due to brain pulsation. The prostate scans showed that sd-DWI can provide similar ADC compared with EPI diffusion, with no image distortion. Patient scans showed that the sequence can clearly depict joint lesions.An sd-DWI sequence was developed and optimized. Compared with conventional EPI diffusion, sd-DWI provided similar diffusion contrast, accurate ADC measurement, improved image quality, and minimal ambient scanning noise. The sequence showed the ability to obtain in vivo diffusion contrast in relatively motion-free body regions, such as prostate and joint.

    View details for DOI 10.1002/mrm.28106

    View details for PubMedID 31782557

  • CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison Irvin, J., Rajpurkar, P., Ko, M., Yu, Y., Ciurea-Ilcus, S., Chute, C., Marklund, H., Haghgoo, B., Ball, R., Shpanskaya, K., Seekins, J., Mong, D. A., Halabi, S. S., Sandberg, J. K., Jones, R., Larson, D. B., Langlotz, C. P., Patel, B. N., Lungren, M. P., Ng, A. Y., AAAI ASSOC ADVANCEMENT ARTIFICIAL INTELLIGENCE. 2019: 590?97

Footer Links:

Stanford Medicine Resources: