Bio

Stanford Advisors


Publications

All Publications


  • 18F-FPPRGD2 PET/CT in patients with metastatic renal cell cancer. European journal of nuclear medicine and molecular imaging Toriihara, A., Duan, H., Thompson, H. M., Park, S., Hatami, N., Baratto, L., Fan, A. C., Iagaru, A. 2019

    Abstract

    PURPOSE: The usefulness of positron emission tomography/computed tomography (PET/CT) using (18F)-2-fluoropropionyl-labeled PEGylated dimeric arginine-glycine-aspartic acid peptide [PEG3-E{c(RGDyk)}2] (18F-FPPRGD2) in patients with metastatic renal cell cancer (mRCC) has not been evaluated; therefore, we were prompted to conduct this pilot study.METHODS: Seven patients with mRCC were enrolled in this prospective study. 18F-FPPRGD2 and 2-deoxy-2-(18F)fluoro-D-glucose (18F-FDG) PET/CT images were evaluated in a per-lesion analysis. Maximum standardized uptake value (SUVmax) and tumor-to-background ratio (T/B) were measured for all detected lesions, both before and after starting antiangiogenic therapy.RESULTS: Sixty lesions in total were detected in this cohort. SUVmax from 18F-FPPRGD2 PET/CT was lower than that from 18F-FDG PET/CT (4.4±2.9 vs 7.8±5.6, P<0.001). Both SUVmax and T/B from 18F-FPPRGD2 PET/CT decreased after starting antiangiogenic therapy (SUVmax, 4.2±3.2 vs 2.6±1.4, P=0.003; T/B, 3.7±3.2 vs 1.5±0.8, P<0.001). Average changes in SUVmax and T/B were-29.3±23.6% and-48.1±28.3%, respectively.CONCLUSIONS: 18F-FPPRGD2 PET/CT may be an useful tool for monitoring early response to antiangiogenic therapy in patients with mRCC. These preliminary results need to be confirmed in larger cohorts.

    View details for PubMedID 30850872

  • Predicting Response to Immunotherapy by Evaluating Tumors, Lymphoid Cell-Rich Organs, and Immune-Related Adverse Events Using FDG-PET/CT. Clinical nuclear medicine Nobashi, T., Baratto, L., Reddy, S. A., Srinivas, S., Toriihara, A., Hatami, N., Yohannan, T. K., Mittra, E. 2019

    Abstract

    PURPOSE: To investigate whether the evaluation of tumors, lymphoid cell-rich organs, and immune-related adverse events (IRAE) with F-FDG PET/CT can predict the efficacy and outcome of immunotherapy.METHODS: Forty patients who underwent F-FDG-PET/CT scans before and after therapy with immune checkpoint inhibitors from December 2013 to December 2016 were retrospectively enrolled (malignant melanoma, n = 21; malignant lymphoma, n = 11; renal cell carcinoma, n = 8). SUVmax of the baseline and first restaging scans were evaluated in tumors, spleen, bone marrow, thyroid and pituitary glands, and were correlated to best overall response in the first year after therapy; IRAE-affected areas were also evaluated.RESULTS: Interval change between the baseline and first restaging scans showed that patients with a clinical benefit had a significant decrease in tumor parameters (P < 0.001). All patients with an increase of SUVmax in the thyroid of more than 1.5 (n = 5) on the first restaging scan had a complete response (CR) in 1 year. Patients with CR within 1 year (n = 22) were significantly associated with a favorable long-term outcome (P = 0.002). Nine patients with IRAE findings had CR at final evaluation. Among IRAE, thyroiditis was seen significantly earlier than arthritis (P = 0.040).CONCLUSIONS: The decrease of tumor parameters at early time-point PET scans was seen in patients with immunotherapy who had clinical benefit within 1 year. PET-detectable IRAE was useful for prediction of a favorable outcome. Early development of thyroiditis may particularly represent an early response indicator to immunotherapy.

    View details for PubMedID 30688730

  • 18F-florbetaben whole-body PET/MRI for evaluation of systemic amyloid deposition. EJNMMI research Baratto, L., Park, S. Y., Hatami, N., Gulaka, P., Vasanawala, S., Yohannan, T. K., Herfkens, R., Witteles, R., Iagaru, A. 2018; 8 (1): 66

    Abstract

    BACKGROUND: Florbetaben, a 18F-labeled stilbene derivative (Neuraceq, formerly known as BAY-949172), is a diagnostic radiopharmaceutical developed to visualize beta-amyloid plaques in the brain. Here, we report a pilot study evaluating patients with suspected cardiac amyloidosis for systemic extent of disease.METHODS: We prospectively enrolled nine patients, 61-86year old (mean±SD 69.4±8.6), referred from the cardiac amyloid clinic. First, dynamic imaging of the heart was acquired immediately after injection of 222-318.2MBq (mean±SD 270.1±33.3) of 18F-florbetaben using the GE SIGNA PET/MRI. This was followed by a whole-body PET/MRI scan 60-146.4min (mean±SD 98±33.4) after injection. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Whole-body MRI sequences included MRAC and axial T1-weighted imaging.RESULTS: High early uptake and delayed high uptake in the left ventricle correlated with amyloid deposition in five patients, while low uptake on early and delayed cardiac imaging was noted in four patients. Cardiac function measurements were successfully obtained in all participants. Areas of increased abnormal 18F-florbetaben accumulation were noted on delayed whole-body imaging in the bone marrow (seven patients), stomach (diffuse in five patients and focal in one patient), brain (five patients), salivary glands (three patients), tongue (three patients), spleen (three patients), skeletal muscles (three patients), ocular muscles (two patients), thyroid (two patients), pleura (two patients), kidneys (two patients), and lungs (two patients).CONCLUSIONS: Whole-body 18F-florbetaben PET/MRI is promising for localization of systemic amyloid deposition. This technique may provide important structural and functional information regarding the organs involved by disease, with potential to guide biopsy and evaluate response to treatment.TRIAL REGISTRATION: Clinicaltrials.gov registration: NCT03119558 .

    View details for PubMedID 30043115

  • Gallium 68 PSMA-11 PET/MR Imaging in Patients with Intermediate- or High-Risk Prostate Cancer. Radiology Park, S. Y., Zacharias, C., Harrison, C., Fan, R. E., Kunder, C., Hatami, N., Giesel, F., Ghanouni, P., Daniel, B., Loening, A. M., Sonn, G. A., Iagaru, A. 2018: 172232

    Abstract

    Purpose To report the results of dual-time-point gallium 68 (68Ga) prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET)/magnetic resonance (MR) imaging prior to prostatectomy in patients with intermediate- or high-risk cancer. Materials and Methods Thirty-three men who underwent conventional imaging as clinically indicated and who were scheduled for radical prostatectomy with pelvic lymph node dissection were recruited for this study. A mean dose of 4.1 mCi ± 0.7 (151.7 MBq ± 25.9) of 68Ga-PSMA-11 was administered. Whole-body images were acquired starting 41-61 minutes after injection by using a GE SIGNA PET/MR imaging unit, followed by an additional pelvic PET/MR imaging acquisition at 87-125 minutes after injection. PET/MR imaging findings were compared with findings at multiparametric MR imaging (including diffusion-weighted imaging, T2-weighted imaging, and dynamic contrast material-enhanced imaging) and were correlated with results of final whole-mount pathologic examination and pelvic nodal dissection to yield sensitivity and specificity. Dual-time-point metabolic parameters (eg, maximum standardized uptake value [SUVmax]) were compared by using a paired t test and were correlated with clinical and histopathologic variables including prostate-specific antigen level, Gleason score, and tumor volume. Results Prostate cancer was seen at 68Ga-PSMA-11 PET in all 33 patients, whereas multiparametric MR imaging depicted Prostate Imaging Reporting and Data System (PI-RADS) 4 or 5 lesions in 26 patients and PI-RADS 3 lesions in four patients. Focal uptake was seen in the pelvic lymph nodes in five patients. Pathologic examination confirmed prostate cancer in all patients, as well as nodal metastasis in three. All patients with normal pelvic nodes in PET/MR imaging had no metastases at pathologic examination. The accumulation of 68Ga-PSMA-11 increased at later acquisition times, with higher mean SUVmax (15.3 vs 12.3, P < .001). One additional prostate cancer was identified only at delayed imaging. Conclusion This study found that 68Ga-PSMA-11 PET can be used to identify prostate cancer, while MR imaging provides detailed anatomic guidance. Hence, 68Ga-PSMA-11 PET/MR imaging provides valuable diagnostic information and may inform the need for and extent of pelvic node dissection.

    View details for PubMedID 29786490

  • Initial experience with a SiPM-based PET/CT scanner: influence of acquisition time on image quality EJNMMI PHYSICS Sonni, I., Baratto, L., Park, S., Hatami, N., Srinivas, S., Davidzon, G., Gambhir, S., Iagaru, A. 2018; 5: 9

    Abstract

    A newly introduced PET/CT scanner (Discovery Meaningful Insights-DMI, GE Healthcare) includes the silicon photomultiplier (SiPM) with time-of-flight (TOF) technology first used in the GE SIGNA PET/MRI. In this study, we investigated the impact of various acquisition times on image quality using this SiPM-based PET/CT.We reviewed data from 58 participants with cancer who were scanned using the DMI PET/CT scanner. The administered dosages ranged 295.3-429.9 MBq (mean?±?SD 356.3?±?37.4) and imaging started at 71-142 min (mean?±?SD 101.41?±?17.52) after administration of the radiopharmaceutical. The patients' BMI ranged 19.79-46.16 (mean?±?SD 26.55?±?5.53). We retrospectively reconstructed the raw TOF data at 30, 60, 90, and 120 s/bed and at the standard image acquisition time per clinical protocol (180 or 210 s/bed depending on BMI). Each reconstruction was reviewed blindly by two nuclear medicine physicians and scored 1-5 (1-poor, 5-excellent quality). The liver signal-to-noise ratio (SNR) was used as a quantitative measure of image quality.The average scores?±?SD of the readers were 2.61?±?0.83, 3.70 ±?0.92, 4.36?±?0.82, 4.82?±?0.39, and 4.91?±?0.91 for the 30, 60, 90, and 120 s/bed and at standard acquisition time, respectively. Inter-reader agreement on image quality assessment was good, with a weighted kappa of 0.80 (95% CI 0.72-0.81). In the evaluation of the effects of time per bed acquisition on semi-quantitative measurements, we found that the only time point significantly different from the standard time were 30 and 60 s (both with P??25, images can be acquired as fast as 90 s/bed using the SiPM PET/CT and still result in very good image quality (average score >?4).

    View details for PubMedID 29666972

  • Comparison Between Different PET and CT-Based Imaging Interpretation Criteria at Interim Imaging in Patients With Diffuse Large B-Cell Lymphoma CLINICAL NUCLEAR MEDICINE Baratto, L., Davidzon, G. A., Moghbel, M., Hatami, N., Iagaru, A., Mittra, E. S. 2018; 43 (1): 1?8

    Abstract

    To evaluate the predictive value of interim PET (iPET) in diffuse large B-cell lymphoma (DLBCL) using 5 different imaging interpretation criteria: Deauville 5-point scale criteria, International Harmonization Project (IHP) criteria, Response Evaluation Criteria In Solid Tumors (RECIST) 1.1, European Organization for Research and Treatment of Cancer, and PET Response Criteria in Solid Tumors (PERCIST) 1.0.We retrospectively reviewed records from 38 patients with DLBCL who underwent baseline and iPET at our institution. Imaging was interpreted according to the previously mentioned criteria. Results were correlated with end-of-treatment response, based on reports at the end of treatment radiological examinations, overall survival (OS), and progression-free survival (PFS) to assess and compare the predictive value of iPET according to each criterion. We also evaluated the concordance between different criteria.The Deauville and PERCIST criteria were the most reliable for predicting end-of-treatment response, reporting an accuracy of 81.6%. They also correlated with OS and PFS (P = 0.0004 and P = 0.0001, and P = 0.0007 and P = 0.0002, for Deauville and PERCIST, respectively). Interim PET according to European Organization for Research and Treatment of Cancer also predicted the end-of-treatment response with an accuracy of 73.7% and had a significant correlation with OS (P = 0.007) and PFS (P = 0.007). In contrast, the IHP criteria and RECIST did not predict outcomes: the accuracy for end-of-treatment response was 34.2% and 36.8%, respectively, with no significant correlation with OS or PFS (P = 0.182 and P = 0.357, and P = 0.341 and P = 0.215, for OS and PFS, respectively).The predictive value of iPET in DLBCL patients is most reliable using the Deauville and PERCIST criteria. Criteria that rely on anatomical characteristics, namely, RECIST and IHP criteria, are less accurate in predicting patient outcomes in DLBCL.

    View details for DOI 10.1097/RLU.0000000000001880

    View details for Web of Science ID 000418319900001

    View details for PubMedID 29076913

  • 18F-FDG silicon photomultiplier PET/CT: A pilot study comparing semi-quantitative measurements with standard PET/CT. PloS one Baratto, L., Park, S. Y., Hatami, N., Davidzon, G., Srinivas, S., Gambhir, S. S., Iagaru, A. 2017; 12 (6)

    Abstract

    To evaluate if the new Discovery Molecular Insights (DMI) PET/CT scanner provides equivalent results compared to the standard of care PET/CT scanners (GE Discovery 600 or GE Discovery 690) used in our clinic and to explore any possible differences in semi-quantitative measurements.The local Institutional Review Board approved the protocol and written informed consent was obtained from each patient. Between September and November 2016, 50 patients underwent a single 18F-FDG injection and two scans: the clinical standard PET/CT followed immediately by the DMI PET/CT scan. We measured SUVmax and SUVmean of different background organs and up to four lesions per patient from data acquired using both scanners.DMI PET/CT identified all the 107 lesions detected by standard PET/CT scanners, as well as additional 37 areas of focal increased 18F-FDG uptake. The SUVmax values for all 107 lesions ranged 1.2 to 14.6 (mean ± SD: 2.8 ± 2.8), higher on DMI PET/CT compared with standard of care PET/CT. The mean lesion:aortic arch SUVmax ratio and mean lesion:liver SUVmax ratio were 0.2-15.2 (mean ± SD: 3.2 ± 2.6) and 0.2-8.5 (mean ± SD: 1.9 ± 1.4) respectively, higher on DMI PET/CT than standard PET/CT. These differences were statistically significant (P value < 0.0001) and not correlated to the delay in acquisition of DMI PET data (P < 0.0001).Our study shows high performance of the new DMI PET/CT scanner. This may have a significant role in diagnosing and staging disease, as well as for assessing and monitoring responses to therapies.

    View details for DOI 10.1371/journal.pone.0178936

    View details for PubMedID 28582472

Footer Links:

Stanford Medicine Resources: