  • Improved slice-selective adiabatic excitation.

    Balchandani P, Glover G, Pauly J, Spielman D. Magn Reson Med. 2013

    PURPOSE: The purpose of this work is to design an improved Slice-selective Tunable-flip AdiaBatic Low peak-power Excitation (STABLE) pulse with shorter duration and increased off-resonance immunity to make it suitable for use in a greater range of applications and at higher field strengths. An additional aim is to design a variant of this pulse to achieve B(1) -insensitive, fat-suppressed excitation. METHODS: The adiabatic SLR algorithm was used to generate a more uniform spectral pulse envelope for this improved radiofrequency pulse for adiabatic slice-selective excitation, called STABLE-2. Pulse parameters were adjusted to design a version of STABLE-2 with a spectral null centered on lipids. RESULTS: In vivo images obtained of the human brain at 3 and 7 T demonstrate that STABLE-2 provides robust, uniform, slice-selective excitation over a range of B(1) values. Phantom and in vivo knee images obtained at 3 T demonstrate the effectiveness of STABLE-2 for fat suppression. CONCLUSIONS: STABLE-2 achieves B(1) -insensitive slice-selective excitation while providing greater off-resonance immunity and a shorter pulse duration, when compared to the original STABLE pulse. In particular, the 9.8-ms STABLE-2 pulse provides slice selectivity over 120 Hz whereas the 21-ms STABLE pulse is limited to 80 Hz off-resonance. B(1) -Insensitive fat-suppressed excitation may also be achieved by using a variant of this pulse. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.