  • Fiberoptic light source-induced surgical fires -- the contribution of forced-air warming blankets.

    Williams DM, Littwin S, Patterson AJ, Brock-Utne JG. Acta Anaesthesiol Scand. 2006; 50 (4): 505-8

    Fiberoptic light sources have been identified as a fire ignition mechanism in the operating room. This study attempted to determine whether a forced-air warming blanket (FAWB) could affect the ignition or spread of fire caused by a fiberoptic light source.