Magnetic resonance imaging of articular cartilage of the knee: comparison between fat-suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy.
J Magn Reson Imaging. 2004; (5): 857-64
To compare signal-to-noise ratios (S/N) and contrast-to-noise ratios (C/N) in various MR sequences, including fat-suppressed three-dimensional spoiled gradient-echo (SPGR) imaging, fat-suppressed fast spin echo (FSE) imaging, and fat-suppressed three-dimensional driven equilibrium Fourier transform (DEFT) imaging, and to determine the diagnostic accuracy of these imaging sequences for detecting cartilage lesions in osteoarthritic knees, as compared with arthroscopy.