Sandy Napel
Publication Details
-
Curved-slab maximum intensity projection: method and evaluation.
Radiology. 2003; (1): 255-60
The authors developed and evaluated a method to produce curved-slab maximum intensity projections (MIPs) through blood vessels that semiautomatically excludes soft tissue and bone. Results obtained with the algorithm were compared with those obtained with rectangular-slab MIPs by using computed tomographic (CT) data from four patients with abdominal aortic aneurysms. Curved-slab MIPs exhibited increased mean vessel-to-perivascular tissue contrast of 55.1 HU (36%), allowed a 10% increase in contrast-to-noise ratio, and decreased apparent vessel narrowing by 0.12-1.09 mm, without increasing processing time. Curved-slab MIPs may also include multiple vessels in a single image, thereby improving interpretation efficiency by reducing the number of MIPs required in these patients from eight to three.