Sanjiv Sam Gambhir, MD, PhD
Publication Details
-
ROC and localization ROC analyses of lesion detection in whole-body FDG PET: effects of acquisition mode, attenuation correction and reconstruction algorithm.
J Nucl Med. 1999; (12): 2043-52
Receiver operating characteristic (ROC) and localization ROC (LROC) studies were performed to compare lesion detection at the borderline of detectability on images reconstructed with two-dimensional filtered backprojection (FBP) without attenuation correction (a common clinical protocol), three-dimensional FBP without attenuation correction, two-dimensional FBP with segmented attenuation correction and a two-dimensional iterative maximum a posteriori (MAP) algorithm using attenuation correction. Lung cancer was the model for the study because of the prominent role of 18F-fluorodeoxyglucose PET in the staging of lung cancer and the importance of lesion detection for staging.