  • The accuracy of human senses in the detection of neonatal heart rate during standardized simulated resuscitation: implications for delivery of care, training and technology design.

    Chitkara R, Rajani AK, Oehlert JW, Lee HC, Epi MS, Halamek LP. Resuscitation. 2013; 84 (3): 369-72

    Auscultation and palpation are recommended methods of determining heart rate (HR) during neonatal resuscitation. We hypothesized that: (a) detection of HR by auscultation or palpation will vary by more than ± 15BPM from actual HR; and (b) the inability to accurately determine HR will be associated with errors in management of the neonate during simulated resuscitation.